Detection method details
Name: |
QL-ELE-00-026 |
Description: |
Qualitative real-time PCR (TaqMan) method for detection of the element coding for phosphinothricin N-acetyltransferase (CS-bar-STRHY) gene from Streptomyces hygroscopicus (partim bar) (Debode et al., 2016). |
Comment: |
Target is the phosphinothricin N-acetyltransferase (CS-bar-STRHY) gene from the bacterium Streptomyces hygroscopicus
For details of the detection of pat (partim pat) by this duplex real-time PCR method refer to QL-ELE-00-025 |
Validation: |
ring trial validation |
Standardisation: |
EU reference method |
Related Methods: |
Type: |
element-specific |
Target DNA element: |
CS-bar-STRHY
|
-
Oligonucleotides:
Forward Primer
Name:
RapB-F1Sequence:
acaagcacggtcaacttccSize:
19
Reverse Primer
Name:
RapB-R1Sequence:
gaggtcgtccgtccactcSize:
18
Probe
Name:
RapB-S1Sequence:
taccgagccgcaggaaccSize:
18
-
Amplicon:
Sequence:
acaagcacggtcaacttccgtaccgagccgcaggaaccgcaggagtggacggacgacctcSize:
60
Documents
Citation | Type | Local copy |
---|---|---|
Debode F., Huber I., Macarthur R., et al. (2016) Inter-laboratory studies for the validation of two singleplex (tE9 and pea lectin) and one duplex (pat/bar) real-time PCR methods for GMO detection. Food Control, 73, 452-461![]() |
peer-reviewed article | 26-04-2023 |
EU-RL GMFF GMOMETHODS database; QL-ELE-00-026![]() |
EU reference method protocol | 26-04-2023 |